MTI Weigh Systems, Inc

We accept Visa and MasterCard
 

Digital Load Cells

Digital Canister Load Cell Model MTI-RTCSP-D

APPLICATIONS: road weighbridges, rail weighbridges, high capacity process weighing.
FEATURES / SIZE, CAPACITY & PRICE SPECIFICATIONS / TECHNICAL SPECIFICATIONS

The Digital Canister Compression Load Cell is a multi-column, low profile, stainless steel, compression load cell with a digital out put signal.

This digital output enables the user to communicate with each Digital Canister load cell independently of the others in the system, thus offering advantages in load cell and weigh system setup, weigh system control, corner correction, fault finding and load cell replacement.

FEATURES

Digital Compression Load Cell

  • Digital output via RS485 or RS422 interface
  • Low profile, multi-column, fully stainless steel construction
  • Hermetically Sealed, IP66/68
  • Certified to OIML R-60, 4000d
  • Internal diagnostics
  • Internal lightning protection
  • 240,000 counts resolution
  • Maximum transmission distance: 1200 meters
  • Capacities: 10 - 100 ton

Return to top of page

 

SIZE, CAPACITY & PRICE SPECIFICATIONS

Dimensions are mm, unless otherwise noted.

Drawn Dimensions of the SCC Digital Compression Load Cell
Capacity
in Tons
5, 10, 25 40 60 100
A 73.0 105.0 152.4
B 31.8 58.7 79.2
C 152.0 152.0 423.0
D 6.5 8.0 23.6
E 82.5 127.0 184.2
F 7.0 29.0 67.5
G 58.0 82.5 123.8
H M12 x 1.75
11 Deep
M20 x 2.5
20 Deep
I 1.5 11.0 21.8
J 78.6 98.2 124.0
K 50.0
L 25.0
M ½" NTP
Accuracy
Class
D3 D3 D3 D3
List Price $1,555.00 $1,650.00 $1,735.00 $2,215.00

Return to top of page

 

TECHNICAL SPECIFICATIONS

SPECIFICATIONS: SCC Digital Load Cell

Standard Capacities (=Emax) t   10, 25, 40, 60, 100
OIML R-60 Accuracy Class   CC C2 C3 C4
Max. num Verification Intervals(nlc)     2000 3000 4000
Min. Verification Intervals(Vmin)    

Emax/10000

Min. Utilisation %   20 30 40
Min. Verification Interval Type MR       Emax/20000
Min. Utilization Type MR %     15 20
Combined Error %S <+0.0500 <+0.0230 <+0.0200 <+0.0173
Non- Repeatability %S <+0.0200 <+0.0100 <+0.0100 <+0.0090
Creep Error (30 minutes) %S <+0.0600 <+0.0245 <+0.0245 <+0.0184
Min. Dead Load %Emax

0

Max. Safe Overload %Emax

150

Max. Safe Side Load %Emax 10
Excitation Voltage Vdc

11.6...17.0

Rated Output counts 240,000
Rated Output Tolerance counts

<+ 200

Zero Balance counts <+ 200
Insulation Resistance ohms

>+ 5000

Sealing  

(DIN40.050 / EN60.529 / IEC 529)
IP 66/68

Signal update per sec.  

25

Baud Rate bit/s

9600

Parity  

Even

Max. Transmission Cable length m

1200

Data Transmission Interface  

RS485 / RS 422 - Full Duplex

Compensated Temp Range °C

-10 to +40

Return to top of page

For more information about this Digital Canister Load Cell, Model MTI-RTCSP-D,
please phone 1-888-684-9344,
or email us at: staff@mti-weigh.com,
or fill out our quote form.

 

Site Map

MTI Weigh Systems, Inc.
33 Mainsail Drive
N. Kingstown, RI 02852


Phone: 401.583.0096
Toll Free: 888.MTI-Weigh